Tower crane monitoring system

Intelligent collision avoidance

This system (tower crane static anti-collision system) is a system used to limit the tower crane working area when there are fixed facilities such as high-voltage lines, roads and super tall buildings in the operation area. When the tower crane enters the restricted area, the sound and light warning is carried out, and the control is carried out when entering the dangerous area. Its simple installation and operation can help tower crane operators avoid serious safety accidents caused by operating errors. By using this effective auxiliary device, the efficiency of construction work can be greatly improved and a safer working environment can be provided. There is a high-voltage line scheme one in the operation range of the tower crane (protect the high-voltage line through scaffolding, passive defense

This system (tower crane static anti-collision system) is used for tower crane in the operation area of high-voltage lines, roads and super tall buildings and other fixed facilities , a system that limits the working area of the tower crane. When the tower crane enters the restricted area, the sound and light warning is carried out, and the control is carried out when entering the dangerous area. Its simple installation and operation can help tower crane operators avoid serious safety accidents caused by operating errors. By using this effective auxiliary device, the efficiency of construction work can be greatly improved and a safer working environment can be provided.

Image keywords

There are high-voltage lines within the operating range of the tower crane

Image keywords

Solution 1 (protect the high-voltage line through scaffolding, passively prevent the tower crane from colliding with the high-voltage line and causing accidents)

Image keywords

Scheme 2 (through the static anti-collision system, the tower crane alarms before entering the prohibited area, and the tower crane is restricted from entering the area when approaching the prohibited area, and can only operate in a safe direction)



Technical parameters

  • Instrument dimensions: 203×128×55 (MM);

  • Instrument working environment temperature (indoor): -20°C~+60°C

    Storage temperature: -30°C~+70°C; Protection class: IP23

  • Sensor (outdoor) working temperature: -30°C~+60°C

    Special requirements low temperature type: -60°C~+80°C; Protection grade: IP65 or above

  • Relative humidity: ≤95%RH (25°C)

  • Working mode: continuous

  • Alarm volume: not less than 60dB

  • Power consumption: ≤ 30W

  • System comprehensive error: ≤ ±5%

  • Vibration resistance: Acceleration≤ 5g (g is the acceleration of gravity)

  • Working voltage: AC220V (50Hz-60Hz) (standard type), can be applied to standard generator power supply

  • The number of operating cycles and alarm storage records is greater than 2,<>


serial numberComponent namequantity
Key features
1appearance
1Display system data, data processing, data upload
3Amplitude sensor
1Output the current amplitude data
4Height sensor
1Output the current height data
5Rotary sensors (encoders)1Outputs the current rotation data
6Wind speed sensor1Output the current wind speed data
7Relays2Realize amplitude and rotation control functions